We are offering our clients with PRIORITY LIFTON series which are used in banking, IT, hospitals, educational institutions & various other business set-ups.
Salient Features Environment Friendly: Unlike Diesel Generator, Lifton does not emit smoke, neither it make hoise. So they are absolutely pollution free & environment friendly.
Highly Reliable: Use of selected good quality components, use of proven technologies & following highest st&ards of Engineering practice ensures very high reliability of the product.
Very Flexible: The products in Lifton family are extremely flexible & are available in tailor made configurations & multiple architecture to suit every individual installation requirements.
Easily adaptable: Lifton can support single or more number of Lifts. It is compliant to user specific Programmable logic of operation. In addition, it supports lamps & bulbs to illuminate the area around lift. Therefore, it is adaptable to various operations.
Swift Service: Urgency in dealing with maintenance calls
Type Cost Extra Cost | Static electronics device. Is more economical than Generator. No additional circuitry, acoustic covering (canopy) ft hidden costs. | Electro-mechanical device. Is costlier than ELOS. Requires AMF panels, acoustic covering etc. |
| No load Condition | Utility of battery power is only during operation of the LOAD. | Generator is required to be kept ON in NO LOAD condition also, hence unnecessary usage of fuel Very noisy. |
| Noise Changeover Time Recurring Cost | Absolutely noise less. Auto changeover within few milliseconds. Negligible if maintained properly. | Has to start manually. Fuel (diesel )& maintenance cost is more because of wear & tear due to internal rotary mechanical parts. |
| Life | Life of the equipment is more than Generator. Batteries can last for 3 to 5 years if maintained periodically | Lesser than Lifton. If extended, the expense of alternator & other spares replacement is considerable. |
| Pollution | Absolutely pollution free 6 environmental Friendly. | Emits smoke, fumes & noise |
Priority lifton series: 6KVA/ 180, 8 KVA/ 180 VDC, 10 KVA/ 180 VDC, 15 KVA/ 240 VDC, 20 KVA/ 240 VDC, 25 KVA/ 24OVDC, 30 KVA/ 240 VDC, 80 KVA/ 360 VDC, 100 KVA/ 360 VDC
Technical specifications: • Model: MPS 8000
• Rating: 8 KVA
• AC INPUT: 415V + 15% -20%
• Three Phase Input Frequency: 50Hz ± 6%
• DC VOLTAGE: 180 VDC
• Charging Time: 12 Hours for 90% of full Capacity
• Charger Type: CVCC Internal Controlled Rectifier type
• INVERTER: Technology IGBT Double Conversion
• Output Voltage: 400 / 415V AC
• PWM Sine wave
• Harmonic Distortion: Less than 3% on Linear Load
• Inverter Efficiency > 90%
• Overload: 105% Continuous, 300% for 60 sec
• Crest Factor: 4:1
• Phase Displacement: 1200 ± 10
• Audible Noise: Less than 45 dB at 1 Meter
• GENERAL: Dimensions (LxWxH)mm 740x 350 x 800
• Operating temperature: 00C to 500C
• Humidity: Max 95%
• Non-condensing PROTECTIONS: Output Overload & Short circuit, Output Under & Overvoltage, DC Under & Overvoltage Input Under & Overvoltage, Single Elevator Backup Systems
INDICATIONS & ALARMS • Mains on Indication
• Inverter on Indication
• DC Low Indication & Alarm
• Output Overload Indication & Alarm