On Line UPS Systems
We manufacture for our clients with On Line UPS systems which are True online double conversion type UPS system. These have a wide input voltage tolerance range along with Neat and dean flat cable wiring.
Application
- LCD panel fur power status
- Automatic by-pass
- SNMP connectivity
- Remote control panel
- Network and computer connectivity
Salient Features
- Pure sine wave output
- True online double conversion type UPS system
- High frequency PWM design using ICBT / MOSFET
- Complete fault diagnosis on the front panel
- Wide input voltage tolerance range
- Neat and clean flat cable wiring
- Software interface through RS 232 port for monitoring UPS performance from server
- User friendly, easy to install, use and maintain
Technical Specifications of True Sine wave online UPS System: - Rated output capacity - 0.5KVA to 50KVA
- Input Voltage- a)170- 270 V AC (1) b)355 -475V AC (3)
- Input Frequency: - 45-55 HZ
- Rectifier Charger: -Automatic front turn boo, constant voltage, constant current type
- Output Voltage a)-230V M%(1) b)415V M%{3)
- Output Frequency: -50HZ: /-1%
- Power Factor: -0.8 lagging to unity
- Inverter Efficiency- > 90% on 90% load
- Wave form- Pure sine wave
- Distortion- < 5% for non linear load
- Overload Capacity a)-120% for 10 minutes b)150% for 20 seconds
- Transient response- a)for step load change of 0% to 100% and 100% to 0% b)Output remains within /- 5% and recovers within 5 m secs.
|
'PRIORITY GREEN' 101 Series (1 Ph To 1 Ph)
 | We are offering our clients with PRIORITY GREEN 101 Series (1 PH to 1 PH) including 3 KVA, 5 KVA, 6 KVA, 7.5 KVA. These are precision engineered and have the following features and specifications:
• Model: pps green 3k • Rating: 3 KVA • AC INPUT: 230V + 15% -20% Single Phase Input • Frequency: 50Hz ± 6% • DC VOLTAGE: 144 VDC • Charging Time: 12 Hours for 90% of full Capacity • Charger Type: CVCC Internal Controlled Rectifier type INVERTER:
• Technology: IGBT Double Conversion • Output Voltage: 230V AC Single Phase • Voltage Regulation: ± 1% for DC I/p variation & o/p load variation • Frequency: 50Hz ± 0.05Hz e)Waveform: PWM Sine wave • Harmonic Distortion: Less than 3% • Inverter Efficiency: > 90% • Power Factor: 0.8 • Overload: 150% for 60 sec • Crest Factor: 3:1 • Transient Recovery: ± 4% under full load change and corrected within 60msec • Audible Noise: Less than 45 dB at 1 Meter
GENERAL:
• Dimensions (LxWxH)mm: 640x 240x 500 • Operating temperature: 00C to 500C • Humidity: Max 95%, Non-condensing PROTECTIONS: Output Overload & Short circuit, Output Under & Overvoltage, DC Under & Overvoltage Input Under & Overvoltage, Single Phasing & Phase unbalance
INDICATIONS & ALARMS
• Mains on Indication • Inverter on Indication • DC Low Indication & Alarm • Fault Indication & Alarm • Output Overload Indication & Alarm • Mains fail Indication & Alarm
BYPASS FACILITY
• Manual Bypass Switch (Provided as Standard feature) • Static Bypass Switch (Optional)
Send Enquiry |
'PRIORITY GREEN' 301 Series (3 Ph To 1 Ph)
We are offering our clients with high precision engineered 'PRIORITY GREEN' 301 Series (3 Ph To 1 Ph). These have CVCC Internal Controlled Rectifier type charger which takes 12 Hours for charging up to 90% of full Capacity.
The specifications are as follows: • Model: PPS301 10k
• Rating: 10KVA • AC INPUT: 415V + 15% -20% Three Phase Input • Frequency: 50Hz ± 6% • DC VOLTAGE: 360VDC
INVERTER:
• Technology: IGBT Double Conversion • Output Voltage: 230V AC Single Phase • Voltage Regulation: ± 1% for DC I/p variation & o/p load variation • Frequency: 50Hz ± 0.05Hz • Waveform: PWM Sine wave • Harmonic Distortion Less than 3% • Inverter Efficiency > 92% • Power Factor: 0.8 • Overload: 150% for 60 sec • Crest Factor: 3:1 • Transient Recovery: ± 4% under full load change and corrected within 60msec • Audible Noise: Less than 45 dB at 1 Meter
GENERAL:
• Dimensions (LxWxH)mm: 740x 350x 800 • Operating temperature: 00C to 500C • Humidity: Max 95% • Non-condensing PROTECTIONS : Output Overload & Short circuit, Output Under & Overvoltage, DC Under & Overvoltage Input Under & Overvoltage, Single Phasing & Phase unbalance
INDICATIONS & ALARMS:
• Mains on Indication • Inverter on Indication • DC Low Indication & Alarm • Fault Indication & Alarm • Output Overload Indication & Alarm
BYPASS FACILITY
• Manual Bypass Switch (Provided as Standard feature) • Static Bypass Switch(Optional)
Send Enquiry |  |
'PRIORITY GREEN' 303 Series (3 Ph To 3 Ph)
 | We are offering our clients with PRIORITY GREEN 303 SERIES that includes (3 PH to 3 PH) > 10 KVA, 15 KVA, 20 KVA, 25 KVA, 30 KVA, 40 KVA, 50 KVA, 60 KVA, 80 KVA, 100 KVA. These have Transient Recovery ± 4% under full load change and corrected within 60msec.
The specifications are as follows:
• Model: Priority green 303 10k • Rating: 10 KVA • AC INPUT: 415V + 15% -20% • Three Phase Input Frequency: 50Hz ± 6% • DC VOLTAGE: 360VDC • Charging Time: 12 Hours for 90% of full Capacity • Charger Type: CVCC Internal Controlled Rectifier type • INVERTER: Technology • IGBT Double Conversion • Output Voltage: 400V AC Three Phase • Voltage Regulation: ± 1% for DC I/p variation & o/p load variation • Frequency: 50Hz ± 0.05Hz • Waveform: PWM Sine wave • Harmonic Distortion: Less than 3% • Inverter Efficiency> 92% • Power Factor: 0.8 • Overload: 150% for 60 sec • Crest Factor: 3:1 • Phase Displacement: 1200 ± 10 • Audible Noise: Less than 50 dB at 1 Meter
GENERAL:
• Dimensions (LxWxH)mm: 1040 x 350 x 910 • Operating temperature: 00C to 500C • Humidity: Max 95%, Non-condensing PROTECTIONS: Output Overload & Short circuit, Output Under & Overvoltage, DC Under & Overvoltage Input Under & Overvoltage, Single Phasing & Phase unbalance
INDICATIONS & ALARMS
• Mains on Indication • Inverter on Indication • DC Low Indication & Alarm • Fault Indication & Alarm • Output Overload Indication & Alarm
BYPASS FACILITY:
• Static Bypass Switch(Optional) • Bi-directional